| Version 1026 SP1 |
| 2009-11-04 |
- The automatic daylight saving adjustment to winter time does not work properly. Please reboot the appliance once.
|
| 2009-08-11 |
- In bridge mode outbound emails are not delivered successfully. Please contact our support to get a manually update installed. ==> FIXED in 1.1.348 (WI-Beta)
- Setting the date and time manually from the Admin-GUI may not work in some cases. ==> FIXED
- Restore: After an Appliance-Restore the Appliance may not booting in "Normal mode". Please call the REDDOXX Support if your Appliance do not boot correctly after an restore. ==> FIXED
- Admin console: When using the live log filter functions Filterprocess or smart filter multiple winddows open with error messages. Please use the console version before if you need to have this functionality until this problem is fixed. ==> FIXED
- LDAP-Connector: Error while connecting the LDAP-Server, if you use a short Hostname. Please use the fully qualified domain name (FQDN) or an IP-Address. ==> FIXED
|
| Version 1026 Beta |
| 2009-02-09 |
- Logfiles gets not deleted if - delete without backup - is configured.
==> Fixed
|
| Version 1025 |
| 2008-11-21 |
|
| 2008-11-20 |
- Problem: In a virtual appliance under VMware Server the network is not started.
This results in different error messages during the boot process on the terminal console.
Noticed with: VMware Virtual Server version 1.0.8, but also possible with other 1.0.x versions. Solution: Upgrade to Virtual Server version 2.0. Workaround for 1.0.x-versions: Select in the settings of the virtual maschine the TAB GENERAL, then select Machine Type OTHER -LINUX Kernel 2.6.x. Shutdown the virtual appliance before. In VMware-Server-Version 2.0 the Machine type Ubuntu (recommended) also works. FIXED
|
| 2008-11-19 |
- Problem: In a virtual appliance the time does not run synchroniously with the time given from the VMWare Server itself.
Solution: Start the Remote Support Service and contact our Support. We will solve the problem manually until we will release a service pack in a short period of time. FIXED
|
|
| Version 1025 Beta |
| 2008-11-11 |
- After a canceled cluster creation, when creating the cluster again, the Failover-IP address is prefilled for the primary cluster by mistake.
==> Re-Log in solves the problem. FIXED
- After changing the admin password on launching the diagnostics follwing error message appears: invalid password for control service.
==> Re-Log in solves the problem. FIXED
|
| 2008-11-10 |
- Spam passes the appliance. The Fuzzy filter is not working correctly when using a proxy. FIXED
- BASIC appliances crashes when running a backup FIXED
|
| 2008-11-07 |
- Error in System Upgrade to version 1025 with VMWare Server 1.0.4. Error at Shrink: /dev/hda not found.
==> please use a newer version of VMWare Servers ( >= 1.0.5) LEAVE UNFIXED
- Bayes Filter with error message RC=3. FIXED
|